{"id":124,"date":"2023-10-24T07:36:17","date_gmt":"2023-10-24T07:36:17","guid":{"rendered":"https:\/\/flats.c2n.universite-paris-saclay.fr\/?page_id=124"},"modified":"2024-09-22T15:51:27","modified_gmt":"2024-09-22T15:51:27","slug":"scalability","status":"publish","type":"page","link":"https:\/\/newflats.c2n.universite-paris-saclay.fr\/?page_id=124","title":{"rendered":"Scalability"},"content":{"rendered":"\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-luminous-vivid-orange-color\"><strong>Our Experts:<\/strong> <\/mark><a href=\"nicolas.reckinger@uclouvain.be\">Antonella Cavanna <\/a> (CNRS), <a href=\"nicolas.reckinger@uclouvain.be\">Nicolas Reckinger <\/a>(UCLouvain) and Zhenxing Wang (AMO)<\/p>\n\n\n\n<p>In order to move graphene technologies from the experimental labs to the real technological world we will need to start producing our devices in larger surfaces with a high reproducibility. In order to achieve the large surfaces one of the most used methods is the chemical vapor deposition, or CVD, growth. In the following we will describe the main ingredients for the growth and the advances we have made to improve its quality and to transfer it from its native substrate to any other.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Graphene grown by chemical vapor deposition &#8211; Principle of growth:<\/strong><\/h2>\n\n\n\n<p>Quartz reactor pumped to primary vacuum and returned to atmospheric pressure with argon. Copper foil as catalyst. The furnace is heated to 1050\u00b0C. Once 1050\u00b0C has been reached in the tube, methane and hydrogen are introduced in addition to argon. After a growth time of one to several hours, the tube is slowly cooled down to room temperature.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"871\" height=\"1024\" src=\"https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/06\/CVD_Diagram-2-871x1024.png\" alt=\"\" class=\"wp-image-374\" style=\"width:642px;height:auto\" srcset=\"https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/06\/CVD_Diagram-2-871x1024.png 871w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/06\/CVD_Diagram-2-255x300.png 255w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/06\/CVD_Diagram-2-768x903.png 768w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/06\/CVD_Diagram-2-1307x1536.png 1307w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/06\/CVD_Diagram-2-1742x2048.png 1742w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/06\/CVD_Diagram-2.png 1902w\" sizes=\"auto, (max-width: 871px) 100vw, 871px\" \/><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\"><strong>Improving the quality of CVD graphene on Cu<\/strong><\/h2>\n\n\n\n<p>We have conducted a thorough study on the origin of the unavoidable contaminations at the surface of copper after the CVD process. We have identified two distinct origins for the impurities. The first type is intrinsic impurities, originating from the manufacturing process of the copper foils, already present at the surface before any high-temperature treatment, or buried into the bulk of copper foils. The buried impurities diffuse towards the copper surface during high-temperature treatment and precipitate. The second source is external: silica contamination arising from the quartz tube that also precipitates on copper. The problem of the extrinsic silica contamination is readily solved upon using adequate confinement of the copper foil samples. The intrinsic impurities are much more difficult to remove since they appear spread in the whole foil. Nevertheless, electropolishing proves particularly efficient in drastically reducing the issue (see figure below for comparison). The results of this study are published in N. Reckinger and B. Hackens, <a href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0169433223022353\" data-type=\"link\" data-id=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0169433223022353\">Appl. Surf. Sci. 641, 158555 (2023)<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"362\" src=\"https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/05\/Electropolished-1024x362.png\" alt=\"\" class=\"wp-image-210\" srcset=\"https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/05\/Electropolished-1024x362.png 1024w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/05\/Electropolished-300x106.png 300w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/05\/Electropolished-768x271.png 768w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/05\/Electropolished.png 1093w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><strong>(Left), <em>Optical microscopy image of a graphene sheet synthesized on an electropolished copper foil piece and wet-transferred onto a SiO<\/em><sub>2<\/sub><em>\/Si substrate. (Right) The same graphene sheet grown in an area left unpolished of the copper foil piece.<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Graphene exfoliation from copper and transfer to another substrate<\/strong><\/h2>\n\n\n\n<p class=\"has-text-align-left\">A polymer-based stamp on a glass slide fixed to a home-made micromanipulator is used to perform dry exfoliation of isolated single-layer graphene flakes (several hundreds of microns in size) grown on copper by chemical vapor deposition. The graphene\/copper substrate is immersed beforehand in an aqueous mixture for several hours to oxidize the copper layer underlying graphene.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"370\" data-id=\"185\" src=\"https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/01\/Scalability_UCL_01-1-1024x370.png\" alt=\"\" class=\"wp-image-185\" srcset=\"https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/01\/Scalability_UCL_01-1-1024x370.png 1024w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/01\/Scalability_UCL_01-1-300x108.png 300w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/01\/Scalability_UCL_01-1-768x277.png 768w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/01\/Scalability_UCL_01-1.png 1324w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<figcaption class=\"blocks-gallery-caption wp-element-caption\"><strong>(a) Scanning electron microscopy image of a graphene flake on copper after oxidation of copper underlying graphene. (b) Optical microscopy image of the same area.<\/strong><\/figcaption><\/figure>\n\n\n\n<p>After exfoliation, the graphene flake is transfered onto a 300-nm-thick SiO<sub>2<\/sub>\/Si substrate. One can see that graphene on deeper copper grooves (rolling striations) stays on copper because the polymer is not in contact with graphene before exfoliation. Even though the copper foil is electropolished, the striations still persist. Nevertheless, a sizable chunk of graphene could be exfoliated and nicely transfered.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"420\" src=\"https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/01\/Scalability_UCL_02-1024x420.png\" alt=\"\" class=\"wp-image-186\" srcset=\"https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/01\/Scalability_UCL_02-1024x420.png 1024w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/01\/Scalability_UCL_02-300x123.png 300w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/01\/Scalability_UCL_02-768x315.png 768w, https:\/\/newflats.c2n.universite-paris-saclay.fr\/wp-content\/uploads\/2024\/01\/Scalability_UCL_02.png 1162w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"> <strong>(a) Optical microscopy image of an isolated single-layer graphene flake on copper after contact with the polymer stamp (seen through the glass slide supporting the stamp). (b) Optical microscopy image of the same flake after dry exfoliation and transfer onto a 300-nm-thick SiO<sub>2<\/sub>\/Si subtrate. The white dotted line is a guide to the eye.<\/strong><\/figcaption><\/figure>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Our Experts: Antonella Cavanna (CNRS), Nicolas Reckinger (UCLouvain) and Zhenxing Wang (AMO) In order to move graphene technologies from the experimental labs to the real<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-124","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/newflats.c2n.universite-paris-saclay.fr\/index.php?rest_route=\/wp\/v2\/pages\/124","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/newflats.c2n.universite-paris-saclay.fr\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/newflats.c2n.universite-paris-saclay.fr\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/newflats.c2n.universite-paris-saclay.fr\/index.php?rest_route=\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/newflats.c2n.universite-paris-saclay.fr\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=124"}],"version-history":[{"count":17,"href":"https:\/\/newflats.c2n.universite-paris-saclay.fr\/index.php?rest_route=\/wp\/v2\/pages\/124\/revisions"}],"predecessor-version":[{"id":474,"href":"https:\/\/newflats.c2n.universite-paris-saclay.fr\/index.php?rest_route=\/wp\/v2\/pages\/124\/revisions\/474"}],"wp:attachment":[{"href":"https:\/\/newflats.c2n.universite-paris-saclay.fr\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=124"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}